Poland - Surgical gloves

For more information and to make a bid you will need to go to the third party website.

Details

Provided by Open Opps
Opportunity closing date
06 March 2020
Opportunity publication date
04 February 2020
Category
33141420
Value of contract
£0-100k
Your guide to exporting
Report opportunity

Description

Plastic PE glove, packed in 100 pcs. size L, M - 250 pack. Plastic glove - sterile - individually packaged, made of PE - op. a 100 pcs. M, L op. (100 pieces) 38. Diagnostic latex glove - non-sterile - powder-free (powder content max. 1 mg), multi-purpose - for left and right hand, easy to apply, well-fitting, evenly rolled edge - packed in 100 pieces, gloves according to EN 455 - 1, 2, 3, AQL max. 1.5, breaking load: before aging min. 7N, after aging mines. 6N, length min. 240 mm, protein level < 30μg/g. Tested for virus transmission in accordance with ASTM F 1671. Factory labeled packaging as - medical device and Category III personal protective equipment and CE marking. S, M, L op. (100 pcs.) 400. Diagnostic latex glove - non-sterile - lightly powder-coated with corn starch (powder content 2 mg-10 mg), universal - for left and right hand, easy to apply, well-fitting, evenly rolled edge - packed in 100 pcs. each, breaking strength: before aging min. 7N - after aging min. 6N, gloves according to EN 455-1, 2, 3, AQL max. 1.5, length min. 240 mm, protein level < 80μg/g. Tested for virus transmission in accordance with ASTM F 1671. Factory labeled packaging - as medical device and category I personal protective equipment and CE marking. XS, S, M, L op. (100 pieces) 1,000. Diagnostic and protective nitrile gloves - powder-free - universal shape, AQL < 1.5; length min. 240 mm, finger thickness min. 0,12 mm, hand thickness min. 0,08 mm, cuff min. 0,06 mm; breaking load before aging min. 7N - after aging min. 6N. Gloves registered as Class III medical device and personal protective equipment; according to EN 455-1-2-3; tested for chemical permeation - min. alcohol and aldehyde - according to EN 374-1 (excluding clause 5.3.2), 2, 3 and tested for microbial (virus) permeation - according to ASTM F 1671 (confirmed by an independent laboratory test report). Packaging a 100 pieces. With countable quantities * with the factory applied marking containing the minimum: AQL level, EN 374, EN 455, compliance with the Medical Device Directive MDD 93/42/EEC&2007/47/EC in class I and PPE Directive 89/686/EEC in category III - bearing the CE mark and the number of the notified body. S, M, L op. (200 pieces) 15 000. Diagnostic and protective nitrile gloves for cytostatic contact - powder-free - universal shape, AQL < 1,5; length min. 240 mm, finger thickness min. 0,12 mm, hand thickness min. 0,08 mm, cuff min. 0,06 mm; breaking load before aging min. 7N - after aging min. 6N. Gloves registered as Class III medical device and personal protective equipment; according to EN 455-1-2-3; tested for chemical permeation - min. alcohol and aldehyde - according to EN 374-1 (excluding clause 5.3.2), 2, 3 and tested for the permeation of microorganisms (viruses) - according to ASTM F 1671 (confirmed by an independent laboratory test report); tested for permeation of min. 9 cytostats according to ASTM 6978 (confirmed by an independent laboratory report). Packaging a 100 pcs. with countable quantity * with factory applied marking containing minimum: AQL level, EN 374, EN 455, compliance with MDD 93/42/EEC&2007/47/EC Medical Device Directive 93/42/EEC&2007/47/EC in class I and PPE 89/686/EEC Personal Protective Equipment Directive PPE 89/686/EEC in category III - bearing the CE mark and the number of the notified body. S, M, L op. (200 pieces) 50. powder-free surgical gloves - sterile - latex-free (made of neoprene, polychloroprene or equivalent), anatomical shape - diversified for the right and left hand, thickness: on the finger min. 0,19 mm, on the hand min. 0,17 mm, on the cuff min. 0.15 mm, packed one pair each in paper-foil packaging (extremely resistant to moisture and micro-sealing); gloves according to EN 455 - 1, 2, 3, tested for penetration of chemicals and microorganisms according to EN 374-3, ASTM F 1671; AQL = < 1, length min. 285 mm. 6,0-8,5 pair 3 000. Surgical gloves for double donning - powder-free, sterile, latex, packed in 2 pairs in an envelope, outer glove polymerized on both sides with light-coloured microtextured outer surface. Intense darker colour inner glove with smooth, chlorinated outer surface and polymerised inner surface. Single wall thickness of each glove: on the finger min. 0,20 mm-0,21 mm, on the hand min. 0,19 mm-0,20 mm, on the cuff min. 0.15 mm-0.16 mm, protein level < 30 ug/g; gloves according to EN 455 - 1, 2, 3 and MDD 93/42/EEC & 2007/47/EC in class II a and PPE Directive 89/686/EEC in category I; according to ASTM F 1671, AQL = < 1, both gloves length min. 280 mm. 6.0 to 8.5 a pair 3,500. Surgical gloves - sterile, latex gloves with an inner polymer layer, powder-free, anatomtomical shape - varied for the right and left hand, thickness on the finger 0.22-0.23 mm, on the hand 0.20-0.21 mm and on the cuff 0.18-0,19 mm, packed 1 pair each in foil-paper packaging (extremely resistant to moisture and micro-sealing) - gloves according to PN-EN 455 - 1, 2, 3, tested for penetration of chemical substances and microorganisms according to the standard: PN-EN 374-3, ASTM F1671, protein level max. 30μg/g, AQL = < 1, length min. 285 mm - size 6.0 - 8.5 number of 23 000 pairs.

Opportunity closing date
06 March 2020
Value of contract
£0-100k

About the buyer

Address
Wojewódzki Szpital Specjalistyczny im. J. Gromkowskiego ul. Koszarowa 5 Wrocław 51-149 Poland
Contact
abolewska@szpital.wroc.pl

The deadline to apply for this opportunity has passed.
Visit the opportunities page to find another.

Is there anything wrong with this page?