Poland - Surgical gloves
For more information and to make a bid you will need to go to the third party website.
Details
Provided by
- Opportunity closing date
- 06 March 2020
- Opportunity publication date
- 04 February 2020
- Category
- 33141420
- Value of contract
- £0-100k
- Your guide to exporting
Description
Plastic PE glove, packed in 100 pcs. size L, M - 250 pack. Plastic glove - sterile - individually packaged, made of PE - op. a 100 pcs. M, L op. (100 pieces) 38. Diagnostic latex glove - non-sterile - powder-free (powder content max. 1 mg), multi-purpose - for left and right hand, easy to apply, well-fitting, evenly rolled edge - packed in 100 pieces, gloves according to EN 455 - 1, 2, 3, AQL max. 1.5, breaking load: before aging min. 7N, after aging mines. 6N, length min. 240 mm, protein level < 30μg/g. Tested for virus transmission in accordance with ASTM F 1671. Factory labeled packaging as - medical device and Category III personal protective equipment and CE marking. S, M, L op. (100 pcs.) 400. Diagnostic latex glove - non-sterile - lightly powder-coated with corn starch (powder content 2 mg-10 mg), universal - for left and right hand, easy to apply, well-fitting, evenly rolled edge - packed in 100 pcs. each, breaking strength: before aging min. 7N - after aging min. 6N, gloves according to EN 455-1, 2, 3, AQL max. 1.5, length min. 240 mm, protein level < 80μg/g. Tested for virus transmission in accordance with ASTM F 1671. Factory labeled packaging - as medical device and category I personal protective equipment and CE marking. XS, S, M, L op. (100 pieces) 1,000. Diagnostic and protective nitrile gloves - powder-free - universal shape, AQL < 1.5; length min. 240 mm, finger thickness min. 0,12 mm, hand thickness min. 0,08 mm, cuff min. 0,06 mm; breaking load before aging min. 7N - after aging min. 6N. Gloves registered as Class III medical device and personal protective equipment; according to EN 455-1-2-3; tested for chemical permeation - min. alcohol and aldehyde - according to EN 374-1 (excluding clause 5.3.2), 2, 3 and tested for microbial (virus) permeation - according to ASTM F 1671 (confirmed by an independent laboratory test report). Packaging a 100 pieces. With countable quantities * with the factory applied marking containing the minimum: AQL level, EN 374, EN 455, compliance with the Medical Device Directive MDD 93/42/EEC&2007/47/EC in class I and PPE Directive 89/686/EEC in category III - bearing the CE mark and the number of the notified body. S, M, L op. (200 pieces) 15 000. Diagnostic and protective nitrile gloves for cytostatic contact - powder-free - universal shape, AQL < 1,5; length min. 240 mm, finger thickness min. 0,12 mm, hand thickness min. 0,08 mm, cuff min. 0,06 mm; breaking load before aging min. 7N - after aging min. 6N. Gloves registered as Class III medical device and personal protective equipment; according to EN 455-1-2-3; tested for chemical permeation - min. alcohol and aldehyde - according to EN 374-1 (excluding clause 5.3.2), 2, 3 and tested for the permeation of microorganisms (viruses) - according to ASTM F 1671 (confirmed by an independent laboratory test report); tested for permeation of min. 9 cytostats according to ASTM 6978 (confirmed by an independent laboratory report). Packaging a 100 pcs. with countable quantity * with factory applied marking containing minimum: AQL level, EN 374, EN 455, compliance with MDD 93/42/EEC&2007/47/EC Medical Device Directive 93/42/EEC&2007/47/EC in class I and PPE 89/686/EEC Personal Protective Equipment Directive PPE 89/686/EEC in category III - bearing the CE mark and the number of the notified body. S, M, L op. (200 pieces) 50. powder-free surgical gloves - sterile - latex-free (made of neoprene, polychloroprene or equivalent), anatomical shape - diversified for the right and left hand, thickness: on the finger min. 0,19 mm, on the hand min. 0,17 mm, on the cuff min. 0.15 mm, packed one pair each in paper-foil packaging (extremely resistant to moisture and micro-sealing); gloves according to EN 455 - 1, 2, 3, tested for penetration of chemicals and microorganisms according to EN 374-3, ASTM F 1671; AQL = < 1, length min. 285 mm. 6,0-8,5 pair 3 000. Surgical gloves for double donning - powder-free, sterile, latex, packed in 2 pairs in an envelope, outer glove polymerized on both sides with light-coloured microtextured outer surface. Intense darker colour inner glove with smooth, chlorinated outer surface and polymerised inner surface. Single wall thickness of each glove: on the finger min. 0,20 mm-0,21 mm, on the hand min. 0,19 mm-0,20 mm, on the cuff min. 0.15 mm-0.16 mm, protein level < 30 ug/g; gloves according to EN 455 - 1, 2, 3 and MDD 93/42/EEC & 2007/47/EC in class II a and PPE Directive 89/686/EEC in category I; according to ASTM F 1671, AQL = < 1, both gloves length min. 280 mm. 6.0 to 8.5 a pair 3,500. Surgical gloves - sterile, latex gloves with an inner polymer layer, powder-free, anatomtomical shape - varied for the right and left hand, thickness on the finger 0.22-0.23 mm, on the hand 0.20-0.21 mm and on the cuff 0.18-0,19 mm, packed 1 pair each in foil-paper packaging (extremely resistant to moisture and micro-sealing) - gloves according to PN-EN 455 - 1, 2, 3, tested for penetration of chemical substances and microorganisms according to the standard: PN-EN 374-3, ASTM F1671, protein level max. 30μg/g, AQL = < 1, length min. 285 mm - size 6.0 - 8.5 number of 23 000 pairs.
- Opportunity closing date
- 06 March 2020
- Value of contract
- £0-100k
About the buyer
- Address
- Wojewódzki Szpital Specjalistyczny im. J. Gromkowskiego ul. Koszarowa 5 Wrocław 51-149 Poland
- Contact
- abolewska@szpital.wroc.pl
The deadline to apply for this opportunity has passed.
Visit the
opportunities page
to find another.