Poland - Medical devices

For more information and to make a bid you will need to go to the third party website.

Details

Provided by Open Opps
Opportunity closing date
08 May 2019
Opportunity publication date
29 March 2019
Category
33100000
Value of contract
to be confirmed
Your guide to exporting
Report opportunity

Description

The system enabling simultaneous archiving of four sources of HDS system signal can use more than one recorder (recorder), with one recorder should allow simultaneous recording from at least two sources of video signal HDNagrywarka:PAL signal system, HDTV Possibility of recording data min.:- to built-in memory (min. 2TB, with FIFO queueing),- to USB memory via USB 2.0 and 3 interface.0,- to network locations (SMB/CIFS)- to FTP locations,- directly to the hospital system via DICOM or HL7 (ORU/MDM messages)Video sequence saving in .mpeg2, .mpeg4 and .Selectable recording quality (before. High and standard) for resolutions up to FullHD.Saving photos in at least: .bmp, .jpg and .jpg2000Format at least: .bmp, .jpg and .jpg2000Export photos from recorded video files.Save single frames (images) in the following formats: .jpeg, .bmp, including 1920x1080 pixel resolution for HDTV 1080pixel HDTV sources Editing function - changes the brightness and contrast of saved images.Deleting selected saved images and videos before the procedure is closed.Entering patient information min. The ability to enter information using an external keyboard and mouse.the ability to visually and acoustically (using an optional external loudspeaker, for future expansion) notify when photos are taken and when video recording begins.the video inputs: min. DP, HDMIDevice equipped with min. 6 USBW ports including min. 4 USB 3.0Print standard, automatically generated treatment reports with image data, in XML and HTML formats. Report creation function in .pdf format with entered text data and photos.Modes for simultaneous recording of video signal from two sources (two-channel recording):- time-synchronized (simultaneous start and stop recording for both video sources) - asynchronous (independent start with stop recording for both video sources).The integrated perioperative control card, fully configurable, compatible with WHO recommendations.the function of saving procedures in selected locations in the background to open a new procedure, introduce a new patient and save new images and videos without having to wait for the completion of the recording of previous procedures.Operating system of the device LaunchedIntroduced malware protection software, independent of operating system security patches, allowing you to run only the applications defined in the "white list".the ability to manage user accounts through Active Directory and create different profiles settings for different user accounts.Possibility to connect a barcode scanner to automatically retrieve patient data from the hospital system (if the system is integrated with the HIS system) Possibility to set automatic system time synchronization Manufactured by a reputable manufacturer and should meet international safety standards such as the American FDA and European CE and ISO 13485Powien should provide a CO2 laser beam with a wavelength of 10.600 nanometers (10.6 microns), infraredSupply a red 5mW guidance spot with adjustable intensitySupply a 635 nm guidance spot with the possibility to switch offSupply a laser beam adapted to precise tissue cutting/ablation without excessive thermal damage to adjacent tissuesSupply min. 7 articulated balanced arm with min. length. 135 cm, rotation min. 360 degreesSupply a spot size of no more than 295μm at up to 30 WattPowSupply with a ceramic enclosed tube of Co2 laser, which is excited at radio frequencies and equipped with a continuous power supply (CW) function, Super Pulsation and Pulsation modePowshould have a Super Pulsation mode of at least 15 WattPowshould have a Pulsation mode of at least 30 WattPowshould have repeatable exposure in the range of at least 0.001 s to 1.0 s, which provides a wide range of comfort for the user and precision in surgeryPowshould be able to clean the handle with an airflowPowshould have a min. penetration depth of min. 1.0 mm for the pulsePowshould be microprocessor controlled with self-calibration and touch panelPowPowshould be equipped with a high-resolution colour display with a diagonal measurement of 7 "The display should contain clear information about the set of accessories before starting the desired settingPowshould have a predefined setting of the laryngological proceduresPower 230V, 60HzPowshould have an integrated smoke evacuation system that is synchronised and remotely controlled by the laser systemPowshould be compact, Horizontal systemDimensions of the device max 500*500*200 mmPlease be able to extend the device by other wavelengths of lightPlease have air coolingMass of the device not greater than 35 kgGuarantee a minimum of 24 monthsSimulation of the middle ear drillingSimulation of sinus surgeryBleeding stimulationSet of predefined middle ear training cases, with different anatomy and pathologies based on real clinical casesThe ability to load your own CTP studiesVisualisation of learning curvesVisualisation of exercise objectivesVisualisation on a 3D screen using 3D glassesManipulators with feedback of force (so-called 'force feedback'). force feedbackVirtual navigation systemMonitoring the movement of instruments (drill, mammal, endoscope)Optional function of automatic notifications when the user approaches critical structuresStarting the virtual drill with the foot pedalGuarantee a minimum of 24 monthsContent of the set:- High-resolution 3D screen with 3D glasses - Computer - Built-in functionalities: middle ear surgery, endoscopic sinus surgery, simulation of bleeding - Import of own cases (CT test) - Two manipulators with force feedback function - Trolley for apparatus Optics with a viewing angle of 0°, diameter 4 mm, working length 18 cm, autoclavable. Optics with roller lens system. Information confirming the autoclavability placed on the optics in a verbal form. Graphic or numerical marking of the diameter of a compatible fiber optic cable on the optics. Optics marking also in the form of DataMatrix. 1 Optics with angle 45°, diameter 4 mm, working length 18 cm, autoclavable. Optics with roller lens system. Information confirming the autoclavability placed on the optics in a verbal form. Graphic or numerical marking of the diameter of a compatible fiber optic cable on the optics. Optics marking also in the form of DataMatrix. 1 Optics with angle 70°, diameter 4 mm, working length 18 cm, autoclavable. Optics with roller lens system. Information confirming the autoclavability placed on the optics in a verbal form. Graphic or numerical marking of the diameter of a compatible fiber optic cable on the optics. Optics marking also in the form of DataMatrix. 1 1 Virtual audiometric measurement tool2. Possibility of performing virtual tonal, impedance or otoscopy audiometry examination3. Possibility of personalisation and customisation of the test4. Possibility of testing Weber and Rinni5. Select the virtual patient difficulty level6. Availability of different air and bone transducers7. Password lock to change test and patient settings8. Controlled by a pointing device or predefined keyboard shortcuts9. Test procedure according to the recommendations of the British Society of Audiology10. Optimisation of the hearing instrument fitting test11. Possibility of creating your own test procedures12. Blocking access to predefined patients13. Adapt patient profiles and exercise data to your specific needs14. Free download of the latest exercises and exercise descriptions15. Creation of exams and assessment of studentsControl of audiometric test criteria:16. correct selection of audiometer settings17. correct chronological order in the procedure18. correct masking19. correct selection of the transmitter20. correct definition of hearing thresholds21. compliance with safety guidelines22. patient comfort23. effective use of time24. 1) for individual audiological training for physicians and hearing care professionals - 8 stations26. 2) for course leaders and training managers, enabling the adaptation of patient profiles and exercise data to the specific needs of students and the generation and evaluation of student exams - 1 position27. In the pledge for each workstation a laptop computer with parameters corresponding to the requirements of the system28. Guaranteed minimum 12 months 11 Diamond drill bit 70mm shaft holder diameter 2.35mm ball diameter 0.6mm2 Diamond drill bit 70mm shaft holder diameter 2.35mm ball diameter 0.8mm3 Diamond drill bit 70mm shaft holder diameter 2.35mm ball diameter 1.0mm4 Diamond drill bit 70mm shaft holder diameter 2.35mm ball diameter 1.4mm5 Diamond drill bit diamond length 1.4 mm5 Diamond drill bit length 70mm roller holder diameter 2.35mm ball diameter 1.4 mm5 Diamond drill bit 1.4 mm long. 70mm shaft holder diameter 2.35mm ball diameter 2.7 mm6 Diamond drill bit length 70mm shaft holder diameter 2.35mm ball diameter 4.0 mm7 Diamond drill bit length 70mm shaft holder diameter 2.35mm ball diameter 5.0 mm8 Diamond drill bit length 70mm shaft holder diameter 2.35mm ball diameter 7.0 mm9 Stainless steel drill bit (milling cutter) long. 70mm shaft holder diameter 2.35mm milling cutter diameter 0.6mm10 Stainless steel drill bit (milling cutter) length 70mm shaft holder diameter 2.35mm milling cutter diameter 0.8mm11 Stainless steel drill bit (milling cutter) length 2.35mm. 70mm shaft holder diameter 2.35mm milling cutter diameter 1.4mm12 Stainless steel drill bit (milling cutter) length 70mm shaft holder diameter 2.35mm milling cutter diameter 1.8mm13 Stainless steel drill bit (milling cutter) length 2.35mm. 70mm shaft holder diameter 2.35mm milling cutter diameter 4.0mm14 Stainless steel drill bit (milling cutter) length 70mm shaft holder diameter 2.35mm milling cutter diameter 5.0mm15 Operating scalpel blade length 35mm total length 130mm16 Handle for exchangeable blades length 120mm17 scalpel blades type 15, packaging 100pc18 Ear hook type LUCAE small length 2mm Fig.1 Round corrugated handle length 140mm19 Anatomical tweezers fine corrugated tip 145mm20 Surgical tweezers fine corrugated tip 145mm21 Micro knife working tip bent at an angle of 45 degrees and diameter 1.5mm corrugated handle length. total 160mm22 Ear tongs very delicate straight corrugated tip with dimensions of 4.0 x 0.6mm total length 80mm disassemblable23 Micro-surgical scissors type BELLUCCI very delicate straight sharp blunt working tip with dimensions of 3.5mm, 4.5mm 7.0mm to choose from length. total 80mm disassembled24 Jewellery tweezers 1 x 2 teeth very delicate dimension 0,4mm total length 115mm25 Jewellery tweezers straight very delicate length 120mm smooth handle26 Micro needle type BARBARA sharp, straight, round corrugated handle length. total 160mm27 Micro ear hook type MCGEE folded left, down width 0.5mm round corrugated handle total length 160mm28 Micro sickle-shaped straight knife, round corrugated handle total length 160mm29 Tip for suction of liquids and secretions without ventilation diameter 1.2mml. 90mm30 Tip for suctioning liquids and secretions without ventilation diameter 1.5mm dl. 90mm31 Suction nozzle for suctioning liquids and secretions without ventilation diameter 1.8mm dl. 90mm32 Tip for suctioning liquids and secretions without ventilation diameter 2.0mm dl. 90mm33 Tip for suctioning liquids and secretions without ventilation diameter 2.2mm dl. 90mm34 Tip for suctioning liquids and secretions without ventilation diameter 3.0mm dl. 90mm35 IRIS FINO section scissors type IRIS FINO bent sharp ends length total 115mm36 Osteotom straight width 6mm total length 170mm37 Autopsy knife length 130mm38 Set of laryngological stoneware 128Hz, 256Hz, 512Hz, 1024Hz, 2048Hz Surgical straightener bent on drills with 2.35mm shaft (without lock), slender, with ratio 1:1, without integrated irrigation channel.

Opportunity closing date
08 May 2019
Value of contract
to be confirmed

About the buyer

Address
Instytut Fizjologii i Patologii Słuchu ul. Mokra 17 Nadarzyn 05-830 Poland
Contact
sekretariat@ifps.org.pl

The deadline to apply for this opportunity has passed.
Visit the opportunities page to find another.

Is there anything wrong with this page?