Germany - Erection of non-load-bearing internal partition walls, installation walls, facing walls

For more information and to make a bid you will need to go to the third party website.

Details

Provided by Open Opps
Opportunity closing date
13 November 2024
Opportunity publication date
10 October 2024
Value of contract
to be confirmed
Your guide to exporting
Report opportunity

Description

Erection of non-load-bearing internal partition walls, installation walls, facing formwork and cladding, shaft walls, ceiling skirts and parapets with plasterboard cladding with different fire and sound insulation requirements and, to a lesser extent, with increased corrosion protection C3. Internal wall insulation of the underground garage walls. Execution: New construction component 3 and existing components 1 and 2. UG, EG, OG and attic execution heights UG-OG: up to approx. 4.00 m, DG: up to approx. 5.70 mIntermediate deadlines: - Installation of the substructure + cladding 1st side: BT 1 and 2: 03.03.2025 to 21.03.2025 and 12.05.2025 to 30.05.2025 BT 3: 12.03.2025 to 28.03.2025 and 26.05.2025 to 06.06.2025 - Cladding 2nd side: BT 1 and 2: 07.04.2025 to 25.04.2025 and 10.06.2025 to 27.06.2025 BT 3: 22.04.2025 to 14.05.2025 and 16.06.2025 to 10.07.2025 - Completion of remaining work by 30.07.2025 - Interior wall insulation underground parking garage approx. 40th - 46th week 2025 Overview of essential individual services with quantities:560 m2 non-load-bearing partition walls, H up to 4.00 m, D 125 mm, 2-ply planked with panel type DFIR or planked with panel type DFIR or DFH2IR EN 520, fire protection requirement F30, Rw up to 57 dB, 105 m2 as above, but Rw up to 61 dB, 75 m2 non-load-bearing partition walls, H up to 4.00 m, D 150 mm, 2-ply planked with panel type DFIR or DFH2IR EN 520, fire protection requirement F30, Rw up to 57 dB, 115 m2 non-load-bearing partition walls, H up to 5.70 m, D 125 mm, 2-ply planked with panel type DFIR or DFH2IR EN 520, fire protection requirement F30, Rw up to 57 dB. 85 m2 non-load-bearing partition walls, H up to 5.00 m, D 125 mm, 2-ply planked with panel type DFIR or DFH2IR EN 520, fire protection requirement F90, Rw up to 57 dB, 50 m2 non-load-bearing partition walls, H up to 4.00 m, D 125 mm, 2-ply planked according to requirement incl. steel sheet lamination, fire protection requirement F90-A in fire wall construction, Rw up to 57 dB, 120 m2 non-load-bearing installation walls, H up to 4.50 m, D 200-300 mm, 2-ply planked with panel type DFIR or DFH2IR EN 520. planked with panel type DFH2IR EN 520, without fire protection requirement, Rw up to 57 dB, 590 m2 free-standing facing shell, H up to 4.50 m, D 75-100 mm, 2-ply planked with panel type DFIR or DFH2IR EN 520, without fire protection requirement, 335 m2 free-standing facing shell, H up to 5.70 m, D 125 mm, 2-ply planked with panel type DFIR or DFH2IR EN 520, without fire protection requirement, 335 m2 free-standing facing shell, H up to 5.70 m, D 125 mm, 2-ply planked with panel type DFH2IR EN 520, without fire protection requirement. planked with panel type DFIR or DFH2IR EN 520, without fire protection requirements, 100 m2 Directly attached facing formwork, H up to 5.70 m, D 70 mm, 2-ply planked with panel type DFIR or DFH2IR EN 520, without fire protection requirements, 40 pcs. Cable box-outs, shaft walls up to 5.0 m2, H up to 5.70 m without fire protection requirement, 20 m2 shaft walls, H up to 4.00 m, fire protection requirement F30, 110 m2 shaft walls, H up to 5.50 m, fire protection requirement F90, 75 m2 ceiling aprons, H up to 1.0 m, D125-150 mm, 19 door niches as self-supporting room system, 2 side walls each with ceiling, L approx. 1.20-2.30 m, W approx. 0.80-1.00 m, H approx. 2.50 m, 100 m2 non-load-bearing partition walls, installation walls and facing shells with increased moisture protection C3 and 2-lg. Cladding with cement boards D 12.5 mm for on-site tiling, 60 pcs. Door openings fabricated. 1-leaf door, 15 door openings. 2-leaf door, 650 m sliding ceiling connections walls and facing formwork up to 30 mm, 200 m adaptation walls, facing formwork to roof pitch incl. sliding connection up to 30 mm, 60 m freist. Wall ends, 50 pieces of work on support stands WC, WB, urinal, approx. 1000 kg add substructures made of hollow steel profiles in drywalls, 280 m2 insulation of basement walls with wood wool multilayer boards, D 175 mm.

Opportunity closing date
13 November 2024
Value of contract
to be confirmed

About the buyer

Address
Landratsamt Garmisch-Partenkirchen

The deadline to apply for this opportunity has passed.
Visit the opportunities page to find another.

Is there anything wrong with this page?